Repositorio Dspace

Desarrollo y ensamblaje de un prototipo de control y monitoreo de corpúsculos infecciosos en las salas críticas de los establecimientos de Salud del Perú

Mostrar el registro sencillo del ítem

dc.contributor.advisor Aguirre León, Angel Junior es_PE
dc.contributor.author Traverso Frisancho, Angel Junior es_PE
dc.date.accessioned 2025-02-10T15:50:05Z
dc.date.available 2025-02-10T15:50:05Z
dc.date.issued 2024
dc.identifier.citation Aguirre León, A. J. (2024). Desarrollo y ensamblaje de un prototipo de control y monitoreo de corpúsculos infecciosos en las salas críticas de los establecimientos de salud del Perú [Tesis para optar el título profesional de Ingeniero Electrónico con Mención en Telecomunicaciones]. Repositorio Institucional UCH es_PE
dc.identifier.uri http://hdl.handle.net/20.500.12872/1020
dc.description.abstract Al cierre del año 2023 en el Perú, la contaminación de las salas críticas hospitalarias ha generado una alta concentración de organismos microbiológicos contaminantes del orden de 0.3 a más micras, la época de la pandemia ha evidenciado el alto nivel de contaminación cruzada en el que se encuentran las salas críticas de los establecimientos de salud, lo que da lugar a que el Perú sea el primer país del mundo con una tasa elevada de muertes por COVID-19 en relación con su población territorial. Debido a esto la solución propuesta en esta tesis es el desarrollar y ensamblar en un ambiente controlado a escala un prototipo electrónico para monitorear y controlar el nivel de corpúsculos infecciosos mediante los parámetros de temperatura, humedad relativa, presión y material particulado a través del microcontrolador ESP 32 aplicando la tecnología IoT almacenando los datos en la nube y medidos en tiempo real para una futura réplica en las salas críticas de los establecimientos de salud en el Perú. Se demostró la eficacia del diseño del dispositivo, replicado a escala, en la reducción de corpúsculos infecciosos. Las pruebas realizadas en un entorno controlado permitieron evaluar su desempeño en términos de eficiencia de filtración y su impacto en la calidad del aire interior. Para ello, se midieron y controlaron parámetros como temperatura, humedad, presión y material particulado, de acuerdo con las recomendaciones de las normas ISO 14644 y ASHRAE 170. Este diseño tiene como objetivo su futura implementación en salas de operaciones en establecimientos de salud en Perú, dentro del marco de creación de salas críticas. es_PE
dc.description.abstract By the end of 2023 in Peru, contamination in critical hospital rooms has led to a high concentration of microbiological contaminants measuring 0.3 microns or larger. The pandemic period has highlighted the severe levels of cross-contamination present in the critical care rooms of health facilities, making Peru the country with the highest COVID-19 death rate in relation to its territorial population. In response to this issue, the proposed solution in this thesis is to develop and assemble, within a controlled environment, a scaled electronic prototype designed to monitor and control infectious particulate levels through parameters such as temperature, relative humidity, pressure, and particulate matter using the ESP32 microcontroller. The solution applies IoT technology to store data in the cloud and measure conditions in real-time, with the goal of future replication in the critical rooms of health facilities across Peru. The efficacy of the device design, replicated on a small scale, was demonstrated in the reduction of infectious particulates. Tests conducted in a controlled environment allowed for evaluation of its filtration efficiency and impact on indoor air quality. Key parameters—temperature, humidity, pressure, and particulate matter—were monitored and controlled based on the recommendations of ISO 14644 and ASHRAE 170 standards. This design aims for future implementation in operating rooms of healthcare facilities in Peru, within the framework of creating critical care rooms. es_PE
dc.format application/pdf es_PE
dc.language.iso spa es_PE
dc.publisher Universidad de Ciencias y Humanidades (UCH) es_PE
dc.rights info:eu-repo/semantics/openAccess es_PE
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/ es_PE
dc.subject Corpúsculos infecciosos es_PE
dc.subject Infecciones adquiridas en atención de salud es_PE
dc.subject Filtros HEPA es_PE
dc.subject Sala crítica es_PE
dc.subject Calidad de aire interior es_PE
dc.subject Infectious particulates es_PE
dc.subject Healthcare-acquired infections es_PE
dc.subject HEPA filters es_PE
dc.subject Critical care rooms es_PE
dc.subject Indoor air quality. es_PE
dc.title Desarrollo y ensamblaje de un prototipo de control y monitoreo de corpúsculos infecciosos en las salas críticas de los establecimientos de Salud del Perú es_PE
dc.type info:eu-repo/semantics/bachelorThesis es_PE
thesis.degree.name Ingeniero Electrónico con mención en Telecomunicaciones es_PE
thesis.degree.grantor Universidad de Ciencias y Humanidades. Facultad de Ciencias e Ingeniería es_PE
thesis.degree.discipline Ingeniería Electrónica con mención en Telecomunicaciones es_PE
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#2.02.01 es_PE
renati.author.dni 76585516
renati.advisor.orcid 0009-0006-1401-9177 es_PE
renati.advisor.dni 48999226
renati.type http://purl.org/pe-repo/renati/type#tesis es_PE
renati.level http://purl.org/pe-repo/renati/nivel#tituloProfesional es_PE
renati.discipline 712066 es_PE
renati.juror Llulluy Nuñez, David es_PE
renati.juror Diaz Ataucuri, Daniel es_PE
renati.juror Vílchez Sandoval, Jesus Alberto es_PE
dc.publisher.country PE es_PE
dc.type.version info:eu-repo/semantics/updatedVersion es_PE


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess

REALIZA TU BUSQUEDA


Listar

Mi cuenta


© 2021 Repositorio Institucional - Universidad de Ciencias y Humanidades (UCH)