Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.12872/1020
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorAguirre León, Angel Juniores_PE
dc.contributor.authorTraverso Frisancho, Angel Juniores_PE
dc.date.accessioned2025-02-10T15:50:05Z-
dc.date.available2025-02-10T15:50:05Z-
dc.date.issued2024-
dc.identifier.citationAguirre León, A. J. (2024). Desarrollo y ensamblaje de un prototipo de control y monitoreo de corpúsculos infecciosos en las salas críticas de los establecimientos de salud del Perú [Tesis para optar el título profesional de Ingeniero Electrónico con Mención en Telecomunicaciones]. Repositorio Institucional UCHes_PE
dc.identifier.urihttp://hdl.handle.net/20.500.12872/1020-
dc.description.abstractAl cierre del año 2023 en el Perú, la contaminación de las salas críticas hospitalarias ha generado una alta concentración de organismos microbiológicos contaminantes del orden de 0.3 a más micras, la época de la pandemia ha evidenciado el alto nivel de contaminación cruzada en el que se encuentran las salas críticas de los establecimientos de salud, lo que da lugar a que el Perú sea el primer país del mundo con una tasa elevada de muertes por COVID-19 en relación con su población territorial. Debido a esto la solución propuesta en esta tesis es el desarrollar y ensamblar en un ambiente controlado a escala un prototipo electrónico para monitorear y controlar el nivel de corpúsculos infecciosos mediante los parámetros de temperatura, humedad relativa, presión y material particulado a través del microcontrolador ESP 32 aplicando la tecnología IoT almacenando los datos en la nube y medidos en tiempo real para una futura réplica en las salas críticas de los establecimientos de salud en el Perú. Se demostró la eficacia del diseño del dispositivo, replicado a escala, en la reducción de corpúsculos infecciosos. Las pruebas realizadas en un entorno controlado permitieron evaluar su desempeño en términos de eficiencia de filtración y su impacto en la calidad del aire interior. Para ello, se midieron y controlaron parámetros como temperatura, humedad, presión y material particulado, de acuerdo con las recomendaciones de las normas ISO 14644 y ASHRAE 170. Este diseño tiene como objetivo su futura implementación en salas de operaciones en establecimientos de salud en Perú, dentro del marco de creación de salas críticas.es_PE
dc.description.abstractBy the end of 2023 in Peru, contamination in critical hospital rooms has led to a high concentration of microbiological contaminants measuring 0.3 microns or larger. The pandemic period has highlighted the severe levels of cross-contamination present in the critical care rooms of health facilities, making Peru the country with the highest COVID-19 death rate in relation to its territorial population. In response to this issue, the proposed solution in this thesis is to develop and assemble, within a controlled environment, a scaled electronic prototype designed to monitor and control infectious particulate levels through parameters such as temperature, relative humidity, pressure, and particulate matter using the ESP32 microcontroller. The solution applies IoT technology to store data in the cloud and measure conditions in real-time, with the goal of future replication in the critical rooms of health facilities across Peru. The efficacy of the device design, replicated on a small scale, was demonstrated in the reduction of infectious particulates. Tests conducted in a controlled environment allowed for evaluation of its filtration efficiency and impact on indoor air quality. Key parameters—temperature, humidity, pressure, and particulate matter—were monitored and controlled based on the recommendations of ISO 14644 and ASHRAE 170 standards. This design aims for future implementation in operating rooms of healthcare facilities in Peru, within the framework of creating critical care rooms.es_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad de Ciencias y Humanidades (UCH)es_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/es_PE
dc.subjectCorpúsculos infecciososes_PE
dc.subjectInfecciones adquiridas en atención de saludes_PE
dc.subjectFiltros HEPAes_PE
dc.subjectSala críticaes_PE
dc.subjectCalidad de aire interiores_PE
dc.subjectInfectious particulateses_PE
dc.subjectHealthcare-acquired infectionses_PE
dc.subjectHEPA filterses_PE
dc.subjectCritical care roomses_PE
dc.subjectIndoor air quality.es_PE
dc.titleDesarrollo y ensamblaje de un prototipo de control y monitoreo de corpúsculos infecciosos en las salas críticas de los establecimientos de Salud del Perúes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.nameIngeniero Electrónico con mención en Telecomunicacioneses_PE
thesis.degree.grantorUniversidad de Ciencias y Humanidades. Facultad de Ciencias e Ingenieríaes_PE
thesis.degree.disciplineIngeniería Electrónica con mención en Telecomunicacioneses_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.02.01es_PE
renati.author.dni76585516-
renati.advisor.orcid0009-0006-1401-9177es_PE
renati.advisor.dni48999226-
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales_PE
renati.discipline712066es_PE
renati.jurorLlulluy Nuñez, Davides_PE
renati.jurorDiaz Ataucuri, Danieles_PE
renati.jurorVílchez Sandoval, Jesus Albertoes_PE
dc.publisher.countryPEes_PE
dc.type.versioninfo:eu-repo/semantics/updatedVersiones_PE
Aparece en las colecciones: Ingeniería Electrónica con Mención en Telecomunicaciones



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.